Rhode Island New Construction Incentives |
Lighting & Controls
|
We offer free light fixture savings analysis for your facility. Click Here if you need help with your applications. |
| Code | Device Description | Eligibility Requirements |
Incentive per fixture /control | Spec Sheets | |
|---|---|---|---|---|---|
10 |
Re-lamp and re-ballast of existing fixtures or any new fluorescent fixture with new T8/T5 lamps and electronic ballasts. | Each fixture is composed of a ballast and 1,2,3 or 4 lamps. Only one incentive may be counted per fixture. All customers are eligible for eight foot T8 electronic ballast incentives. See below* |
$10 |
||
30 |
High Efficiency Fluorescent Fixture 2x2 or 2x4 Style: Recessed or surface mounted troffer fixture with parabolic louver (2” to 3” deep cells), prismatic lens, or recessed indirect fixture | Overall fixture efficiency must exceed: • 83% for a prismatic lensed fixture with T-8 lamps only • 75% for 2x4 fixture with parabolic louver (2” to 3 “ deep cells) with T-8 lamps only • 70% for 2x2 fixture with 2” to 3” deep parabolic louver (2” to 3” deep cells) with T-8 lamps only • 70% for 2x2 or 2x4 recessed indirect fixture with T-8, T-5 or long tube compact fluorescent lamps. Special Requirements: Must be a complete new fixture |
$20 |
![]() |
|
32 |
High Efficiency Low Glare Fluorescent Fixtures |
Each unit must include a new troffer type fixture. Overall efficiency must exceed 64% efficiency. In order to optimize glare control, we recommend that design follow IES Standard RP-1 “preferred” criteria for luminescence. | $25 |
||
33 |
High Efficiency Indirect Fluorescent Fixture Style: Indirect suspended low glare fixtures
|
(Code 33 Quick Step Process): • Each 4-foot section contains not more than three (3) T8 or T5 standard output lamps or two (2) T8 or T5 high output lamps • Each Fixture must exceed 80% efficiency • Fixtures must be specifically designed for pendant installation (examples-Pendant Lighting Installation Guide) • Ceiling finish must be white and unobstructed • Fixtures may have a down-light component of no greater than 30% • Fixtures with a down-light component must incorporate glare limiting louvers or a perforated cover shielding the lamps • Pendant length must be at least 16 inches in length (for lengths less then this, the “Custom” approach must be followed) • Fixtures must be installed at a lighting power density 20% below current building codes |
$35 |
![]() |
Neo-Ray_Suspended.pdf T8-_Suspended.pdf |
41 |
4 ft. Fluorescent Fixture with Reflectors Style: Non recessed/ Open Fixture |
Fixtures must be installed 16 feet from the floor or less • T-8 lamps are eligible, T-5 lamps are not • Each fixture must have new reflectors with a minimum reflectivity of 87% or greater. • Up to 20% up-light as an integral fixture feature (typically slots) may be included but only in instances wherewhite or light colored walls and ceilings exist. Special Requirements: Each unit must include a new custom reflector with a minimum reflectivity of 87%. |
$20 |
![]() |
|
41T |
4 ft. Fluorescent Fixture with Reflectors and Tandem Wired Ballasts |
Fixtures must be installed 16 feet from the floor or less • Ballasts must be tandem wired • T-8 lamps are eligible, T-5 lamps are not eligible • Each fixture must have reflectors with a minimum reflectivity of 87% or greater. Up to 20% up-light as an integral fixture feature (typically slots) may be included but only in instances where white or light colored walls and ceilings exist. |
$10 |
![]() |
|
42 |
8 ft. Fluorescent Fixture with Reflectors
| Fixtures must be installed 16 feet from the floor or less • T-8 lamps are eligible, T-5 lamps are not eligible • Each fixture must have new reflectors with a minimum reflectivity of 87% or greater. Up to 20% up-light as an integral fixture feature Special Requirements: Each unit must include a new custom reflector with a minimum reflectivity of 87%. |
$25 |
![]() |