Rhode Island Existing Facility Incentives |
Lighting & Controls
Program Overview Eligible Equipment Lists |
We offer free light fixture savings analysis for your facility. Click here if you need help with your applications. |
| Code | Device Description | Eligibility Requirements |
Min. Watts | Incentive per fixture /control | Spec Sheets | |
|---|---|---|---|---|---|---|
10 |
Re-lamp and re-ballast of existing fixtures or any new fluorescent fixture with new T8/T5 lamps and electronic ballasts. Style: Recessed or surface mounted fixture with parabolic louver or prismatic lens |
Each fixture is composed of a ballast and 1,2,3 or 4 lamps. Only one incentive may be counted per fixture. All customers are eligible for eight foot T8 electronic ballast incentives. | 5 |
$10 |
||
11 |
Re-lamp and re-ballast of existing fixtures or any |
Two or more fixtures that share a common ballast. Fixtures that share multiple ballasts for the purposes of multi level switching are not eligible. Special Requirements: Must have two or more fixtures sharing a common ballast. (Tandem-wired) |
8 |
$24 /pair of fixtures |
||
30 |
High Efficiency Fluorescent Fixture 2x2 or 2x4 Style: Recessed or surface mounted troffer fixture with parabolic louver (2” to 3” deep cells), prismatic lens, or recessed indirect fixture |
Overall fixture efficiency must exceed: • 83% for a prismatic lensed fixture with T-8 lamps only • 75% for 2x4 fixture with parabolic louver (2” to 3 “ deep cells) with T-8 lamps only • 70% for 2x2 fixture with 2” to 3” deep parabolic louver (2” to 3” deep cells) with T-8 lamps only • 70% for 2x2 or 2x4 recessed indirect fixture with T-8, T-5 or long tube compact fluorescent lamps. Special Requirements: Must be a complete new fixture |
11 |
$40 |
![]() |
|
32 |
High Efficiency Low Glare Fluorescent Fixtures 2x2 or 2x4 Style: Low glare recessed or surface mounted troffer 2x2 or 2x4 fixture with parabolic louver (4” to 5” deep cells) |
Each unit must include a new troffer type fixture. Overall efficiency must exceed 64% efficiency. In order to optimize glare control, we recommend that design follow IES Standard RP-1 “preferred” criteria for luminescence. | 19 |
$65 |
||
33 |
2x4 Advanced Recessed Fluorescent Fixture |
Fixtures must incorporate advanced glare reducing diffusers. Overall fixture efficiency must be 75% or greater. Fixture must be equipped with 1 to 2 T5, T5HO (48 in nominal length only) or eligible High Performance T8 (32 Watt only). Results of photometric analysis must be provided for a typical space in the facility showing illuminance (foot-candles). For 2x2 fixtures, use Code 30. |
14 |
$65 |
Neo-Ray_Suspended.pdf T8-_Suspended.pdf |
|
41 |
4 ft. Fluorescent Fixture with Reflectors Style: Non recessed/Open Fixture |
Fixtures must be installed 16 feet from the floor or less • T-8 lamps are eligible, T-5 lamps are not • Each fixture must have new reflectors with a minimum reflectivity of 87% or greater. • Up to 20% up-light as an integral fixture feature (typically slots) may be included but only in instances wherewhite or light colored walls and ceilings exist. Special Requirements: Each unit must include a new custom reflector with a minimum reflectivity of 87%. |
7 |
$30 |
![]() |
|
41T |
4 ft. Fluorescent Fixture with Reflectors and |
Fixtures must be installed 16 feet from the floor or less • Ballasts must be tandem wired • T-8 lamps are eligible, T-5 lamps are not eligible • Each fixture must have reflectors with a minimum reflectivity of 87% or greater. Up to 20% up-light as an integral fixture feature (typically slots) may be included but only in instances where white or light colored walls and ceilings exist. |
6 |
$20 |
![]() |